I used Omron's K3GN panel meters in a project at work and I had to draw the alphabet in the configuration drawing because it is so unintuitive. It's not a whole lot worse than the one shown in the article, but still... it's pretty rough. I think I prefer numbered parameters like you typically see on VFDs. It's a lot easier to just scroll to P148 or whatever, enter to view/modify, scroll the value, enter to set. Menu trees on seven-segment interfaces are a mistake.

Page six shows the alphabet: https://www.myomron.com/downloads/1.Manuals/Panel%20Indicato...

I wonder how they display "S5" or "5S"